MV Power Cables

3.3Kv to 33Kv Grade - (BASEC/KEMA/CPRl/ERDA tested) three core Copper / Aluminium Conductor,Conductor screened with extruded semi-conducting compound, XLPE Insulated, insulation screened with semiconducting compound in combination with copper tape (0.3 KA for One Sec.), PVC ST2/FR/FRLSH/LSZH Inner Sheathed armoured/ GI Steel (Aluminium in case of single core) FLAT/Round Armoured and Overall PVC ST2/ FR/ FRLSH/ LSZH sheathed cable conforming to IS:7098/ll/85, IEC 60502-2/ BS 7835 From sizes 35 sq.mm to 1200 Sq.mm, above cables can be supplied with lead sheath whenever required.

MV Single Core Power Cables

3.3kv to 33kv grade-(BASEC/KEMA/CPRl/ERDA Tested) Single core copper /Aluminium Conductor, Conductor screened with extruded semi-conducting compound (11KV E & above), XLPE Insulated, Insulation screened with semiconducting compound (11KV E & above) in combination with copper tape , Unarmoured/ Aluminium Flat Strip / Round Wire Armoured and verall PVC ST2/ FR/ FRLSH/ LSZH sheathed cable conforming to IS:7098/ll/85, IEC 60502-2/ BS 7835 From sizes 35 sq.mm to 1200 Sq.mm above cables can be supplied with lead sheath whenever required.

LV Power Cables

Copper/Aluminium solid/stranded conductor, XLPE insulated, cores laid up, PVC inner sheathed, unarmoured/armoured, extruded PVC/PE /LSZH sheathed cables with rated voltage 0.6/1.0 kV from 1.5 mm² to 1000 mm² in 1/2/3/3.5/4 Cores confirming to BS 5467/BS 6724/IEC 60502-1

LV Control Cables

1100 Volts Grade- (BASEC/KEMA/CPRI/ERDA tested) Control Copper Cables, Solid/Stranded conductor, PVC/XLPE/HR PVC Insulated, Cores laid up, PVC/ HR PVC/ FR/ FRLSH/ LSZH Taped/Extruded Inner Sheathed, Unarmoured/ GI Steel (Round Wire/Flat Strip) Armoured, Extruded PVC/ HR PVC/ FR/ FRLSH/ LSZH Outer Sheathed, cables from 2 to 100 crore in 1.5 and 2.5.sq.mm as per IS 1554(Part1) / IS 7098(Part1) 1998 and Generally confirming to IEC60502-1/BS 5467/BS 6724.

Instrumentation Cables

Instrumentation cable for low voltage 300V, 500V application.
These cables are used in various industries for transmission of analog /digital signals for measurement and process control purpose.
Instrumentation cable for low voltage 300V, 500V application.
These cables are used in various industries for transmission of analog/digital signals for measurement and process control purpose.
  • Operating temperature: 70°C & 90°C (depends upon the selection of insulation compound).
  • Product Sizes: 0.50 Sq.mm to 4 Sq.mm up to 48 Pairs/Triads/ Quad element/cores.
  • Conductor: Annealed bare Copper/tinned Copper, solid or stranded Copper conductor (IEC -60228 Class 1 & 2).
  • Insulation Compound: PVC/TI 51/TI 53/PE/XLPE.
  • Screening: Individual & Overall screening with Al-Mylar, Polyester tape and drain wire.
  • Armouring: Galvanized round wire, and Flat strip conforming to IS/BS standard.
  • Sheathing: PVC/FR/FRLS/FROR/LSF Inner & Outer sheath.
Characteristics of Instrumentation Cables
0.5mm2
0.75mm2
1.0mm2
1.5mm2
2.5mm2
Unit
Mutual Capacitance Core to Core
(PVC insulation)
<
250
250
250
250
250
pF / m
Mutual Capacitance Core to Core
(Polyethylene XLEP insulation)
<
115
115
115
115
115
pF / m
L/R Ratio
25
25
25
40
60
µH / Ohm
Conductor Resistance
(D.C.Resistance at 20°C)
<
39.7
26.5
18.4
12.3
7.41
Ohms - Km
Insulation Resistance PVC
>
100
100
100
100
100
M Ohms - Km
Insulation Resistance Polyethlene / XLPE
>
5000
5000
5000
5000
5000
M Ohms - Km
Core - Core / Screen / Armour
Insulation Resistance at 500 V (PVC)
>
25
25
25
25
25
M Ohms - Km
Screen to Screen Insulation Resistance at 500 V
>
1
1
1
1
1
M Ohms - Km

Thermocouple Cables

Thermocouple cables are used to sense process temperature and are connected to the controllers for indication & control.

  • Operating temperature: 70°C & 90°C(depends upon selection of Insulation compound).
  • Range: 20 AWG to16 AWG (KX / VX / KXA / JX / TX / NX etc.).
  • Voltage grade: 300/ 500V, 600V.
  • Insulation : PVC/ PE/ XLPE.
  • Colour code Insulation / Outer sheath: As per the relevant standard.
  • Screening: Individual & Overall screening with Al-Mylar, Polyester tape and drain wire.
  • Armouring: Galvanized round and Flat strip conforming to IS/ BS Standard.
  • Sheathing: PVC/ FR/ FRLS/ FROR/ LSF Inner & Outer sheath.